Applied Flow Technology

How to Fill as Quadratic

Filters and screens impose a pressure drop that varies with flow rate. The variation is non-linear, but manufacturers will often provide only one data point for pressure loss at the design flow rate. Using a single point, or constant pressure drop, can produce significant inaccuracies in your model. With this in mind, AFT offers the “Fill As Quadratic” option for entering loss data.   Using only a single point, “Fill As Quadratic” will create two additional points for you. This first is simply 0,0; zero flow produces zero pressure drop. The second point is 2 x Flow and 4 x Pressure...
Continue reading
  3137 Hits
  0 Comments
Applied Flow Technology

Printing Input and Output

You can print all of or select portions of your model data window in order to have a hard copy of your input. Likewise you can print all of or select portions of your output window in order to have a hardcopy of the output. Printing both of these windows allows you to have hardcopies and backups of everything you would need to perform calculation checks on your model. After building your model and entering all of the required data, browse to the Model Data window and click “View/Model Data Control”. After setting up the input data to be displayed, click...