=== AFT xStream Version 2 (2022.12.12) (Build 1105) === -- Changes that affect results --- 1. Fixed issue where steady state results were not balancing the flow at branches that had pipes connected to pressure reducing flow control valves. 2. Fixed issue where negative enthalpy values from REFPROP were causing incorrect mid-calculations of static temperature resulting in branch iteration convergence issues during the transient. --- Changes that affect interface --- None --- Other changes --- None === AFT xStream Version 2 (2022.12.02) (Build 1104) === -- Changes that affect results --- 1. Fixed an issue where a Mach number exceeds maximum limit warning could be given if a local iteration produces a high Mach number before it is converged. --- Changes that affect interface --- None --- Other changes --- 1. Fixed REFPROP issue that did not affect results, but did not close handles after it was done with them. This was causing the software to crash in some instances. === AFT xStream Version 2 (2022.10.10) (Build 1102) === -- Changes that affect results --- 1. Fixed a problem where the compressor BEP is not calculated when a model is reloaded so it displayed as N/A. It now displays the correct values. 2. Fixed an issue that caused User Additional Losses to not be written to the model file appropriately. User Additional Losses would be erased when re-opening the file. 3. Fixed an issue that caused the Output Warnings to fail while loading if any triggered warnings referenced objects with the pipe symbol ("|") as part of their name. 4. Fixed a problem generating AFT Arrow Steady graph where no data would be displayed. 5. Fixed an issue with inline spray junctions where they could get into a choked flow state incorrectly when the true flow was subsonic. 6. Modified the behavior of spray junctions with no CdA Sonic defined. Previously, these sprays would mimic a choked flow calculation in exit configuration. Now, no spray junction will do a choked calculation unless specifically directed to by the user via provision of a CdA Sonic. Both before and after this change the user was/will be presented with a Warning. --- Changes that affect interface --- 1. Fixed an issue that could cause Relief Valve Pressure Units to be reset to default after opening the property form in specific configurations. 2. Fixed an issue that caused Output Control Format files to be written incorrectly. --- Other changes --- 1. Put in a fix for the Chempak eLicense check on model run === AFT xStream Version 2 (2022.06.08) (Build 1100) === --- Initial Release ---